Cooling towers are ideal environments for microbial growth due to their warm, aerated water. Without proper biocide treatment, this poses significant operational and health risks. Unchecked biological contamination costs the U.S. industrial sector an estimated $100 billion annually from biofouling, reduced efficiency, and corrosion.

Critically, these towers breed dangerous pathogens like Legionella pneumophila. In 2018, nearly 10,000 Legionnaires’ disease cases were reported with a 10% fatality rate, often linked to cooling tower outbreaks. Failing to manage microbial growth jeopardizes equipment integrity and public health.

Biofilm, a sticky slime formed by microbes, causes biofouling that insulates surfaces, reduces heat transfer, and accelerates corrosion. Second, it poses a significant health risk.

The unchecked growth of pathogens, particularly Legionella pneumophila, can lead to serious public health hazards. Effective biocide treatment is not about simply adding a chemical; it requires a strategic, multi-faceted approach.

This strategy requires continuous monitoring and a planned rotation of different biocides to maintain compliance and operational efficiency. Our blog post dives deeper into these practices, offering actionable tips and insights to help you implement an effective approach with ease.

Understanding the Biological Threats

To combat these threats, you must first understand them. How do these microscopic organisms cause such significant problems?

Biofilm Formation (Biofouling)

Biofilm is a complex, sticky layer of microbes, their waste products, and the polymers (polysaccharides) they secrete to protect themselves. This layer adheres tenaciously to heat exchanger tubes and cooling tower fill surfaces. Its impact is severe.

Insulation:

Biofilm forms a dense, insulating layer on surfaces, significantly reducing heat transfer efficiency. This increases energy consumption as systems need to work harder to maintain optimal cooling.

For instance, in cooling towers, a thin biofilm layer as small as 0.1 mm can reduce efficiency by up to 30%, leading to higher operational costs.

Clogging:

Biofilm physically clogs distribution nozzles, filters, and pipes, restricting water flow and disrupting the cooling process. This can cause uneven water distribution, reduced system performance, and even complete system shutdowns.

A common example is in HVAC cooling systems, where clogged nozzles lead to hotspots and uneven cooling across buildings, affecting overall comfort and system reliability.

Corrosion:

Biofilm promotes localized corrosion by creating microenvironments under its deposit, a phenomenon known as Under Deposit Corrosion (UDC). This type of corrosion weakens metal surfaces and can lead to leaks or equipment failure.

For example, in industrial cooling systems, UDC can cause premature damage to heat exchangers and piping, requiring costly repairs or replacements.

The Pathogen Risk: Legionella

What makes a cooling tower a potential public health hazard? It is the risk of pathogenic bacteria, with Legionella being the most critical. This is precisely why effective Biocide Treatment is essential for controlling these dangerous microorganisms.

The Danger: This bacterium thrives in the warm water temperatures of 20°C to 45°C (68°F to 113°F) that are common in cooling towers. It can become aerosolized in the water droplets that exit the tower as drift and can then be inhaled by people nearby, causing the severe pneumonia known as Legionnaires’ Disease.

The Mandate:

  • Due to this serious risk, regulatory bodies and public health agencies mandate strict control and routine monitoring of microbial levels in cooling water systems.
  • Proactive management is not just a best practice; it is a legal and ethical requirement.
  • If contamination is severe, it may require immediate attention, including comprehensive cooling tower repair and decontamination protocols.

The Biocide Arsenal: Two Strategic Classes

How can you effectively control such a diverse range of microbial threats? The most effective treatment programs utilize a powerful combination of two distinct classes of biocides.

Oxidizing Biocides (Rapid Kill & Primary Control)

These chemicals are the frontline defense in a cooling water treatment program. How do they work so quickly? Their mechanism involves oxidizing, or chemically destroying, the microbial cell membrane and its internal proteins, leading to rapid cell death.

  • Chlorine (Cl₂) / Hypochlorite (NaOCl): This is an economical and highly effective option, but its performance diminishes at higher pH levels, and it can be corrosive to system metals if not properly controlled.
  • Bromine (Br₂) / Bromine Compounds: Bromine is more stable and remains highly effective at the higher pH levels typically found in modern cooling tower programs, making it a superior choice in many applications.
  • Chlorine Dioxide (ClO₂): This is an excellent biocide for penetrating and destroying biofilms and is highly effective against pathogens like Legionella. It also maintains its efficacy across a wide pH range.

The only reliable way to measure the active strength of these biocides is by monitoring the Oxidation-Reduction Potential (ORP) of the water.

Non-Oxidizing Biocides (Broad Spectrum & Rotation)

These chemicals provide a different, more targeted mode of attack. How do they complement their oxidizing counterparts? This form of biocide treatment disrupts specific biological functions within the microbe, such as interfering with respiration, DNA replication, or nutrient absorption. While they act more slowly, their specificity is crucial.

Common Chemicals:

A range of chemistries fall into this category, including:

  • Isothiazolins: Broad-spectrum biocides effective against bacteria, fungi, and algae.
  • Glutaraldehyde: Acts by cross-linking proteins, disrupting cellular function.
  • DBNPA (2,2-Dibromo-3-nitrilopropionamide): A fast-acting biocide, often used for shock treatment due to its rapid kill and biodegradability.
  • THPS (Tetrakis Hydroxymethyl Phosphonium Sulfate): Particularly effective against sulfate-reducing bacteria and biofilms.
  • Quaternary Ammonium Compounds (Quats): Disrupt cell membranes, leading to cell death.
  • Biguanides: Act on the cell membrane and inhibit enzyme activity.
  • Bronopol (2-Bromo-2-nitropropane-1,3-diol): Effective against a wide range of bacteria, yeasts, and molds.

Use Case:

When faced with a sudden microbial surge, these biocides deliver a powerful “shock” to restore balance quickly. More importantly, they are your strategic weapon in a rotational program.

By regularly alternating them with your primary oxidizing biocide, you prevent microbes from developing resistance, ensuring your entire biocide treatment strategy remains effective and your system stays protected in the long run.

Ensuring we use the right materials is key when selecting and installing cooling tower parts to resist corrosion from these powerful chemicals.

The Optimized Treatment Strategy

A successful biocide program is more than just chemicals; it is a comprehensive strategy. What does this optimized approach involve?

The Mandatory Biocide Rotation

Microorganisms are incredibly adaptive and can develop resistance if exposed to the same chemical continuously. How do you prevent this?

  • Implement a strict biocide rotation schedule. 
  • Use an oxidizing biocide for primary, continuous control. 
  • Periodically introduce a non-oxidizing biocide as a shock treatment. 
  • This approach ensures a comprehensive kill and prevents microbes from developing immunity.

Biofilm Penetration: The Role of Dispersants

Even the most potent biocides can struggle to be effective if they cannot reach their target. The protective slime matrix of a mature biofilm often shields the microbes underneath.

  1. The Need for Biodispersants: Even potent biocides can’t effectively eliminate microbes hidden within the protective matrix of a mature biofilm.
  2. What are Biodispersants? They are specialized chemical formulations, typically unique blends of surfactants and polymers.
  3. How They Work:
    • They physically and chemically disrupt the biofilm’s extracellular polymeric substance (EPS) matrix.
    • This action loosens and disperses the biofilm structure, effectively breaking it apart.
    •  By dislodging and exposing the embedded microbes, they make them vulnerable.
  4. Enhanced Biocide Efficacy: This allows the biocide to penetrate deep into the deposit, ensuring a more thorough kill of underlying microbes and preventing regrowth.
  5. Strategic Application: Biodispersants are often applied as a pre-treatment or concurrently with biocides to maximize their effectiveness, especially in systems with persistent biofouling.

If your current equipment is unable to handle advanced treatment programs, you may need to consider procuring new cooling towers entirely.

Continuous Monitoring and Control

You cannot manage what you do not measure. What are the key control parameters for a biocide program?

ORP Control:

Using an ORP sensor and controller is the industry standard for managing oxidizing biocide dosage. The system maintains a target ORP level (typically 650-800 mV), ensuring that the active chemical residual is consistently present at a sufficient concentration to kill microbes without being overly corrosive.

Microbial Testing:

Regular testing is necessary to validate the program’s effectiveness. This can include simple dip slides, more advanced ATP (Adenosine Triphosphate) analysis, or specific lab culture testing for Legionella. These results confirm that your biocide strategy is working as intended.

Your Path to a Secure System

Effective biocide treatment is a proactive, multi-step process that protects both operational efficiency and public health. It demands a strategic approach that goes beyond simple chemical dosing, requiring a well-planned rotation program, precise monitoring, and the use of supporting chemistries.

To ensure your cooling system is protected, plant managers should take the following actions.

  • Implement a strict oxidizing/non-oxidizing biocide rotation schedule.
  • Install and calibrate ORP controllers for real-time, automated dosage management.
  • Integrate biodispersants into the program to maximize biocide penetration and remove existing biofilm. If you’re starting from scratch, we can help you design and build new cooling tower systems with the optimal metallurgy and control infrastructure already integrated.

Contact ICST today for a comprehensive biocide audit. We can design a customized, ORP-controlled chemical program that ensures Legionella compliance and maintains peak system performance.

Final Thoughts

Biocide treatment forms the core of every successful cooling tower maintenance program. It eliminates biofilm, controls Legionella bacteria, and keeps the entire system performing efficiently. 

When facility operators use both oxidizing and nonoxidizing biocides in rotation, supported by biodispersants and continuous monitoring, they maintain clean and stable water systems. Regular testing and ORP-based control help prevent microbial growth, reduce corrosion, and improve cooling efficiency.

A consistent biocide program improves performance, lowers operational costs, and protects public health. Partner with ICS Thailand to implement a customized biocide treatment plan that maximizes system reliability, extends equipment life, and ensures long-term compliance.

Frequently Asked Questions

What is a biocide treatment? 

A biocide treatment is the strategic chemical dosing used to kill, control, and prevent the growth of microorganisms (bacteria, algae, and fungi) in water systems. Its vital function is to prevent biofouling and eliminate dangerous pathogens, especially Legionella.

Is biocide toxic to humans? 

Yes, biocides are inherently toxic chemicals designed to kill living cells. They can pose risks (e.g., inhalation or skin/eye irritation) to personnel if mishandled or if the system is overloaded. 

How long does a biocide treatment last? 

A biocide treatment offers significantly longer-lasting microbial control than simple cleaning. You can expect the preventative effect to last 18 to 36 months on average (1.5 to 3 years), and potentially up to 5 years in optimal, well-maintained conditions.

What is a biocide used for?

In industrial water treatment, biocides are used primarily to prevent biofouling (slime growth), improve heat transfer efficiency, prevent corrosion, and control pathogens like Legionella pneumophila.

What is the difference between oxidizing and non-oxidizing biocides?

Answer:

  • Oxidizing Biocides (e.g., Chlorine, Bromine): Work quickly by chemically destroying the microbial cell membrane. Used for continuous, primary control and measured by ORP.
  • Non-Oxidizing Biocides (e.g., Glutaraldehyde): Work more slowly by interfering with specific cellular functions. Used for periodic shock treatments and rotation to prevent resistance.

What is the best biocide for Legionella control?

Chlorine dioxide (ClO₂) is one of the most effective biocides against Legionella due to its strong oxidizing properties, ability to penetrate biofilms, and stability across a wide pH range.

Can biocide treatment damage cooling tower materials?

Yes, improper dosing or incompatible chemicals can corrode metal components. Always ensure correct concentration, pH control, and compatible materials when designing or upgrading cooling tower systems.

Relevant blogs