ICST · Fans category
ICST logo International Cooling Solutions (Thailand)
MenuClose

Cooling tower fans in Thailand

Cooling tower fans move the air that carries heat out of the tower, so the fan sets the airflow and a large part of the tower's power demand. Fan selection affects thermal performance, energy use and reliability. International Cooling Solutions (Thailand), known as ICST, supplies FRP and aluminum cooling tower fans and fan assemblies, including Hudson TUF-LITE, Howden PRO and Moore Class 10000 series, for industrial cooling towers, cooling tower systems and air coolers in Thailand. We select replacement fans to suit the required airflow and the unit's operating conditions.

Request a fan quote Call +66 2 661 7723

Three-panel image of a cooling tower fan hub with blades: in a frame, front view and close-up of the hub.

This page is for plant engineers and maintenance teams who need a replacement cooling tower fan or an upgrade. It shows the fan series we supply, how to choose between FRP and aluminum cooling tower fan blades, and what to send for a quote.

Cooling tower fans we supply

19 fan selections

Series, sizes and specifications
  • Hudson TUF-LITE II 3000 Series fan assemblies.

  • Hudson TUF-LITE III hub fan assemblies: 3000K Series; 3000KC Series, 8 ft to 10 ft with 4 to 15 FRP blades; 3000KUHT and 4000KWUHT Ultra Hi Temp series, rated for up to 350°F continuous air temperature.

  • Hudson TUF-LITE IV hub fan assemblies: 4000M Series, 11 ft to 16 ft, with 4 to 12 carbon fiber and fiberglass blades; 4000MUHT Ultra Hi Temp; 5000M Series, 18 ft to 30 ft; 5000MM Series, 32 ft to 33 ft; 6000MM Series, 34 ft and 36 ft. Fan assemblies are available from 11 ft to 36 ft for cooling towers and air coolers.

  • Howden PRO D-Series, 26 ft to 36 ft (7.93 m to 10.98 m): highly efficient tower fans that combine high aerodynamic performance with low power consumption.

  • Howden PRO E-Series, 4 ft to 48 ft (1.22 m to 14.63 m): versatile, low-vibration and chemically resistant fans.

  • PRO SX Series, 28 inch to 34 ft.

  • Moore Class 10000 aluminum fans for cooling towers and air-cooled heat exchangers: Heavy Duty Standard Chord, with adjustable blade angles; Heavy Duty Extended Chord; XC, with a blade profile designed to increase airflow while reducing operating noise; and MAG (Minimum Acoustic Geometry), engineered for ultra-low-noise applications. Moore Class 20000 fans are designed for large-diameter cooling towers and Class 1000 fans for smaller systems. Moore fans are designed to run smoothly with variable frequency drives (VFDs).

Fans by brand and series

ICST supplies the cooling tower fan series below. Each name opens the product page with its specifications, documents and what to send for a quote. If your fan is not listed, send the nameplate and photos and our parts team will check the match.

Howden PRO D Series

Howden PRO E Series

Howden PRO FPX Series

Howden PRO SX Series

Hudson TUF-LITE II

Hudson TUF-LITE III

Hudson TUF-LITE IV

Moore Class 10000

Moore Class 20000

Moore Class 1000

FRP or aluminum cooling tower fan blades?

The blade material is the first choice when you replace a cooling tower fan.

  • FRP fan blades: single-piece fiberglass reinforced plastic blades, a composite material that can be molded with the twist and taper of an efficient airfoil design. FRP offers corrosion resistance and resists chemical exposure, has low weight compared with aluminum, and is balanced and interchangeable as a set.

  • Aluminum fan blades: extruded or cast metal blades, usually bolted or riveted to a spar. Aluminum can suit small fans with low tip speeds and dry, non-corrosive air, and Moore Class 10000 blades and hubs are also offered in marine-grade aluminum for humid and salty air. Metal blades have a finite fatigue life under cyclic loading and are balanced on site.

Airfoil shape, chord and twist affect static efficiency, so the fan blade design matters as much as the fan diameter, and material properties decide how the blade copes with moisture and chemicals. Our FRP vs aluminum fan blades chart compares construction, balance, interchangeability and efficiency.

How to choose a cooling tower fan

  • Fan speed, fan diameter and number of blades.

  • The environment: corrosive water, salty air or high air temperature (Ultra Hi Temp series).

  • Noise limits at the site: tell us if the site is noise-sensitive, so we can compare low-noise blade profiles such as Moore XC and MAG.

  • The required airflow volume and static pressure, and the tower size.

  • The system resistance: the fan must overcome the resistance of the louvers, fill media and drift eliminators.

  • The motor power and the amp draw you want to keep.

  • Your preventive maintenance plan and inspection intervals.

Fan efficiency and fan-power outcomes depend on fan selection, speed, pitch and system resistance, and aerodynamic blade design affects airflow and energy use, so we confirm the fan against your tower, crossflow or counterflow, and its design airflow before quoting.

What to send for a cooling tower fan replacement quote

Complete our Fan Inquiry Form and add it to your request. It asks for:

  • owner, location, number of fans, and the bid and delivery dates;

  • fan details: diameter, speed, number of blades, airflow and static pressure;

  • motor details: power rating, full-speed RPM, shaft diameter, keyway, frame size, starts per day, single or two-speed, VFD and reversing;

  • gearbox details: manufacturer, model, ratio and shaft.

Photos and the nameplate help our parts team confirm the fit. The fan, gearbox and drive shaft are the mechanical components of the fan drive, so a fan replacement is a good time to check them together, including the gearbox and motor bearings and any excessive vibration.

Fan Inquiry Form (PDF)

Cooling tower fan questions

Should I choose FRP or aluminum fan blades?

FRP suits corrosive water and air and is balanced and interchangeable as a set. Aluminum can suit small fans with low tip speeds and dry, non-corrosive air. The right choice depends on fan speed, environment, required airflow and your maintenance plan.

Can you supply fans for high-temperature air?

Yes. The Hudson TUF-LITE III 3000KUHT and 4000KWUHT and TUF-LITE IV 4000MUHT Ultra Hi Temp series are rated for up to 350°F continuous air temperature.

Do you have fans for noise-sensitive sites?

Moore Class 10000 XC and MAG fans use blade profiles designed to reduce operating noise, and MAG is engineered for ultra-low-noise applications. Tell us the site noise limit and our parts team compares the options.

What size fan do I need?

The fan diameter, speed, number of blades, airflow and static pressure must match your tower and drive, including induced draft towers. Send the Fan Inquiry Form or the nameplate and our parts team confirms the selection.

Do you supply fans for air coolers?

Yes. TUF-LITE IV fan assemblies and Moore Class 10000 fans are supplied for cooling towers and air-cooled heat exchangers.

What do I need to replace the fan gearbox or drive shaft too?

Send the gearbox manufacturer, model and ratio, and the drive shaft length. Our gear box and drive shaft assembly pages list what we supply.

Need a replacement cooling tower fan?

Send the Fan Inquiry Form, your tower model and photos, and our parts team will confirm the fan and quote. Request a fan quote or call our Bangkok team on +66 2 661 7723.

Request a quote

ICST

This website does not set any cookies itself. Our security provider, Cloudflare, sets the cookies listed below to protect the site, and the site keeps two items of browser storage in your current tab. We list the browser storage here too, although it is not a cookie.

Language links

If you use a language link, the page opens on Google Translate (translate.goog). Google may set its own cookies on its own domain, under Google’s terms. We do not control them.

Your choices

Close the browser tab to clear the stored items. Choose “Start over” in the quote form to clear an unsent request. You can also block or delete cookies and site data in your browser settings. Blocking the security cookies may stop the quote form or other pages from working.

Analytics and advertising

We do not use analytics tools or advertising cookies. We will update this notice before we start.

Service providers and effective date

Z.com hosting in Thailand, which hosts the website and the system where requests are stored.

Cloudflare, which provides content delivery and security protection and sets the cookies listed above.

Effective date: 13 November 2026. Questions: use the form on our contact page.